Specifications |
Parameters |
General |
Model |
T7200 series |
Display |
§ 51.3 x 75.5 mm (5 lines) monochrome LCD |
Battery life |
Approximately 500 measurements with 4 new standard alkaline “AA” batteries and inflating the cuff to 160mmHg at a room temperature of 22°C |
Control buttons (soft key) |
§ ON/OFF § BP § CASP § MEMORY |
Display |
Parameters |
§ Systolic pressure in mmHg § Diastolic pressure in mmHg § Pulse rate in BPM (Beats Per Minute) § Central aortic systolic pressure in mmHg |
Pulse Waveform |
Real-time radial arterial pulse waveform |
Plot area range |
§ Auto-scalable Y-axis, digital value of 0 to 4395 § X-axis, 10 seconds |
Blood Pressure & CASP Measurement |
Calibration method |
Oscillometric, performed before use |
Measurement site |
§ Arm (left or right) for blood pressure measurement § Radial artery at the wrist (left or right) for wave acquisition |
Cuff inflation method |
Automatic, by electric pump |
Cuff deflation method |
Electronic control valve (modulated) |
Rapid pressure release method |
Electronic control valve (open) |
Blood pressure measurement time |
Less than 45 seconds (typically) |
Blood pressure range |
40 to 280 mmHg |
Measurement accuracy |
Meets ANSI/AAMI SP10:1992 Standard |
Pulse waveform acquisition device |
Radial pulse wave acquisition device |
Pulse waveform acquisition method |
Modified applanation tonometry |
Pulse rate range |
30 to 180 beats/minute |
Pulse rate accuracy |
±3% |
Pulse waveform acquisition time |
Approximate 10 seconds |
Memory capacity |
200 sets of blood pressure measurements and CASP readings |
Auto power off time |
5 minutes of non-use |
Dimensions and Weight |
Main unit dimensions |
W117 x D131 x H86 mm (W4,6 x D5,2 x H3,4 inch) |
Main unit weight |
Approximately 330g (12 oz.) |
Environmental |
Operating conditions |
· 10°C to 40°C · 15% to 90% relative humidity (non-condensing) · 80 to 106 kPa atmospheric pressure |
Storage conditions |
· -20°C to 50°C · 10% to 95% relative humidity (non-condensing) |
Others |
Cuffs |
· Regular adult cuff, for arm circumferences 21 to 30cm (8.3 to 11.8 inches), (included with system) PART NUMBER: P1500B · Large adult cuff, for arm circumferences 29 to 42 cm (11.4 to 16.5 inches) (optional)
PART NUMBER: P1501B |
Patient safety |
Automatic cuff deflation if any of the following conditions is encountered: · Cuff pressure exceeds 290 mmHg · Measurement time exceeds 180 seconds · Safety timer detects microprocessor failure |
Regulatory |
Electrical safety |
· IEC60601-1:3.Ed. |
EMC |
· IEC60601-1-2:2007 · FCC Part 18 |
Safety |
· EN 1060-1:2002 · EN 1060-3: 1997 |
Class |
· Class IIa, in accordance with EC directive 93/42/EEC (Medical Device Directive) Annex IX rule 10, Patient applied part type BF |
Performance |
· ANSI/AAMI SP10:1992 |
Environmental |
· MIL-STD810F |